Review




Structured Review

ADInstruments ecg recording bioamp
Ecg Recording Bioamp, supplied by ADInstruments, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/ecg recording bioamp/product/ADInstruments
Average 90 stars, based on 1 article reviews
ecg recording bioamp - by Bioz Stars, 2026-04
90/100 stars

Images



Similar Products

90
ADInstruments ecg recording bioamp
Ecg Recording Bioamp, supplied by ADInstruments, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/ecg recording bioamp/product/ADInstruments
Average 90 stars, based on 1 article reviews
ecg recording bioamp - by Bioz Stars, 2026-04
90/100 stars
  Buy from Supplier

90
ADInstruments 3-lead ecg recording equipment bioamp
3 Lead Ecg Recording Equipment Bioamp, supplied by ADInstruments, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/3-lead ecg recording equipment bioamp/product/ADInstruments
Average 90 stars, based on 1 article reviews
3-lead ecg recording equipment bioamp - by Bioz Stars, 2026-04
90/100 stars
  Buy from Supplier

98
ADInstruments ecg ad instruments powerlab 8 30 recorder with bioamp electrodes
Experimental setup. (A) Layout of mouse organs susceptible to translation inhibitors. Organs marked in green are permeable for both harringtonine and cy-cloheximide within 15 sec post-injection. Translation elongation rate can be directly measured in these organs. Testes (shown in yellow) are partially permeable, and brain is mostly unaffected by inhibitors. (B) High doses of harringtonine severely drop heartbeat rate. We established that 2.5 mg/ml had no effect on the beat rate, whereas 5 mg/ml decreased it twice. 10 mg/ml caused cardiac arrest in most of the cases. All injections were done in a tail vein - injection volume was 200 μ l and the weight of mice was 20-25 g. (C) Representative <t>electrocardiograms</t> <t>(ECG)</t> from injected mice. The upper track shows the slowdown of the beat rate in response to 5 mg/ml harringtonine. The lower track shows no difference after the injection of 2.5 mg/ml harringtonine. The effect of harringtonine appears roughly 20 sec after the injection. The red line marks the injection event.
Ecg Ad Instruments Powerlab 8 30 Recorder With Bioamp Electrodes, supplied by ADInstruments, used in various techniques. Bioz Stars score: 98/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/ecg ad instruments powerlab 8 30 recorder with bioamp electrodes/product/ADInstruments
Average 98 stars, based on 1 article reviews
ecg ad instruments powerlab 8 30 recorder with bioamp electrodes - by Bioz Stars, 2026-04
98/100 stars
  Buy from Supplier

90
ADInstruments bioamp ecg recorder
Experimental setup. (A) Layout of mouse organs susceptible to translation inhibitors. Organs marked in green are permeable for both harringtonine and cy-cloheximide within 15 sec post-injection. Translation elongation rate can be directly measured in these organs. Testes (shown in yellow) are partially permeable, and brain is mostly unaffected by inhibitors. (B) High doses of harringtonine severely drop heartbeat rate. We established that 2.5 mg/ml had no effect on the beat rate, whereas 5 mg/ml decreased it twice. 10 mg/ml caused cardiac arrest in most of the cases. All injections were done in a tail vein - injection volume was 200 μ l and the weight of mice was 20-25 g. (C) Representative <t>electrocardiograms</t> <t>(ECG)</t> from injected mice. The upper track shows the slowdown of the beat rate in response to 5 mg/ml harringtonine. The lower track shows no difference after the injection of 2.5 mg/ml harringtonine. The effect of harringtonine appears roughly 20 sec after the injection. The red line marks the injection event.
Bioamp Ecg Recorder, supplied by ADInstruments, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/bioamp ecg recorder/product/ADInstruments
Average 90 stars, based on 1 article reviews
bioamp ecg recorder - by Bioz Stars, 2026-04
90/100 stars
  Buy from Supplier

Image Search Results


Experimental setup. (A) Layout of mouse organs susceptible to translation inhibitors. Organs marked in green are permeable for both harringtonine and cy-cloheximide within 15 sec post-injection. Translation elongation rate can be directly measured in these organs. Testes (shown in yellow) are partially permeable, and brain is mostly unaffected by inhibitors. (B) High doses of harringtonine severely drop heartbeat rate. We established that 2.5 mg/ml had no effect on the beat rate, whereas 5 mg/ml decreased it twice. 10 mg/ml caused cardiac arrest in most of the cases. All injections were done in a tail vein - injection volume was 200 μ l and the weight of mice was 20-25 g. (C) Representative electrocardiograms (ECG) from injected mice. The upper track shows the slowdown of the beat rate in response to 5 mg/ml harringtonine. The lower track shows no difference after the injection of 2.5 mg/ml harringtonine. The effect of harringtonine appears roughly 20 sec after the injection. The red line marks the injection event.

Journal: bioRxiv

Article Title: Organ-specific translation elongation rates measured by in vivo ribosome profiling

doi: 10.1101/279257

Figure Lengend Snippet: Experimental setup. (A) Layout of mouse organs susceptible to translation inhibitors. Organs marked in green are permeable for both harringtonine and cy-cloheximide within 15 sec post-injection. Translation elongation rate can be directly measured in these organs. Testes (shown in yellow) are partially permeable, and brain is mostly unaffected by inhibitors. (B) High doses of harringtonine severely drop heartbeat rate. We established that 2.5 mg/ml had no effect on the beat rate, whereas 5 mg/ml decreased it twice. 10 mg/ml caused cardiac arrest in most of the cases. All injections were done in a tail vein - injection volume was 200 μ l and the weight of mice was 20-25 g. (C) Representative electrocardiograms (ECG) from injected mice. The upper track shows the slowdown of the beat rate in response to 5 mg/ml harringtonine. The lower track shows no difference after the injection of 2.5 mg/ml harringtonine. The effect of harringtonine appears roughly 20 sec after the injection. The red line marks the injection event.

Article Snippet: Heart function was monitored by ECG (AD Instruments, Powerlab 8/30 recorder with BioAmp electrodes).

Techniques: Injection

Measuring translation elongation rate in vivo . (A) ECG monitoring of heart function before and after drug injection to ensure the heart beat rate is unaffected at the chosen dosage. (B) Experimental design for a time-resolved study. (C) Linear regression analysis of injection timepoints to infer the elongation rate. (D) Comparison of mean translation elongation rates in three organs. (E) Metagene analysis of ribosome profiling sequences. Genes longer than 2,000 nucleotides are presented. The first 1,500 nucleotides are shown starting from the first codon of the reading frame. Solid lines represent mean signal from biological replicates, and light shading corresponds to a standard deviation.

Journal: bioRxiv

Article Title: Organ-specific translation elongation rates measured by in vivo ribosome profiling

doi: 10.1101/279257

Figure Lengend Snippet: Measuring translation elongation rate in vivo . (A) ECG monitoring of heart function before and after drug injection to ensure the heart beat rate is unaffected at the chosen dosage. (B) Experimental design for a time-resolved study. (C) Linear regression analysis of injection timepoints to infer the elongation rate. (D) Comparison of mean translation elongation rates in three organs. (E) Metagene analysis of ribosome profiling sequences. Genes longer than 2,000 nucleotides are presented. The first 1,500 nucleotides are shown starting from the first codon of the reading frame. Solid lines represent mean signal from biological replicates, and light shading corresponds to a standard deviation.

Article Snippet: Heart function was monitored by ECG (AD Instruments, Powerlab 8/30 recorder with BioAmp electrodes).

Techniques: In Vivo, Injection, Comparison, Standard Deviation